Dear Barry: We recently installed two, large, double-pane windows in our living room, but we ran into a problem. The weather last night was very cold, and warm air from the floor register caused the glass to crack along the bottom edge of one window. It seems that we made a mistake installing the windows so close to the register. The windows are just a few inches above the floor. What do you think? Trudy

Dear Trudy: The apparent errors in this window installation are worse than you realize. Temperature differentials may indeed have caused the crack, although the cause might have been a flaw in the glass edge, as sometimes occurs when glass is roughly cut. There is, however, a bigger issue.

Windows that are larger than nine square feet and are within 18 inches of the floor must be made of tempered safety glass. The fact that your window cracked, instead of disintegrating into small shards, indicates that it is not safety glass. If someone were to walk into one of these windows, major injuries could result, and you could be liable for the costs of those injuries. My advice is to have these windows replaced by a professional glazing contractor.

The House Detective is distributed by 1000WattConsulting. Do not republish without written consent. To purchase reprint rights please contact marc@1000wattconsulting.com

Questions regarding home inspection please email Barry Stone at questions@housedetective.com

One Comment

  1. [...] warmer weather where winds aren’t as noticeable. However, you should check your windows for these cracks where cold air can come through, resulting in a colder house and higher heating bills due to [...]

Leave a Reply

 

Barry Stone

Barry StoneKnown today as "America's House Detective," Barry advises readers from coast to coast about home inspection and real estate disclosure, providing honest clarity, fresh wit, consumer protection, and even-handed fairness in his responses to real estate questions. Read more.

  Ask The House Detective

  1.  *
  2.  *
  3.  *
  4.  *
  5. captcha


Home Inspections by Barry

    Categories

    Agents Agents referring inspectors Aluminum wiring Asbestos ASHI As is Backdraft Banks Basement Bathroom Bedrooms Breaker panel Builder Liability Builders Building code Building contractors Buyer Beware Carbon Monoxide Central Heating System Certificate of occupancy Chimney Commercial real estate Complaints Concrete concrete pavement Contractor Copper piping Cottage cheese ceiling County Assessor Crawlspace CREIA Damage Deal Killers Demands Disclosure Double tapping Drainage Dryer exhaust ducts Dryrot Electrical Electric Radiant Heat Energy Ethics FHA Appraisers Fire Damage Fire hazards Fireplace Fire wall Forced air French doors Furnace Gas Easement Gas piping Hard wood flooring Heat exchangers Heating System Hidden defects HOA Home inspection career Home Inspector Hot Water HUD Inspection advocacy Inspector Liability Inspector referral Inspector responsibility Insurance integrity International Residential Code Investor Leaks Legal action Liability Lot line Mold Municipal building inspectors NACHI NAHI National Electrical Code New Home New Realtor nternational Residential Code Permits Plumbers Plumbing Polybutlylene Pipe Radon Realtors Red Tagged Red tagged home Roof Safety San Luis Obispo Seller Seller Liability Septic System Setback Sewer line Shady inspection Shower Skylights Tenant Termites Tile roof Toilets Tree roots Uncategorized Unethical Home Inspector Uniform building code Unpermitted addition Unpermitted home Vapor barrier Ventilation Ventless gas fireplace Ventless Gas Fireplaces Ventless Gas Heater Very bad advice Wallpaper Water Heater Water stain Windows