What to do with a flooded crawlspace

Jun 10 2009

The House Detective:  by Barry Stone, Certified Home Inspector

Dear Barry: I recently discovered about 3 to 4 inches of standing water under my house. I pumped out the water and removed the plastic sheets that covered the ground so the soil can dry out. Once the ground is dry, should I spread lime over the surface to help prevent mold? And should I also reinstall the plastic sheets?  Steve

Dear Steve: Mold prevention is not necessary unless you have moisture on cellulose materials. Wet soil will not support mold growth, so there’s no need for lime on the ground.

The purpose of the plastic membrane is to prevent ground moisture from evaporating and causing humidity and condensation in the crawlspace. If faulty ground drainage causes flooding above the plastic, then the plastic serves no useful purpose and does not need to be replaced.

The primary concern in this case is the drainage problem. To solve this, you should have the property evaluated by a geotechnical engineer to determine the water source and the best means of preventing future water intrusion. The engineer might recommend french drains around your home, a sump pump under or around the building, regrading of the ground around the building, or possibly la combination of these. Once this is done, replacement of the plastic membrane may be advisable, but additional foundation vents might also be needed to minimize humidity and condensation.

Finally, you should have the structural framing and subfloor inspected for fungus/dryrot or other moisture-related damage. In subareas with high humidity, rotted wood is common, and repairs can be very costly.

The House Detective is distributed by 1000WattConsulting. Do not republish without written consent. To purchase reprint rights please contact marc@1000wattconsulting.com

Questions regarding home inspection please email Barry Stone at questions@housedetective.com

One Comment

  1. You might consider installing a internal drainage system with a sump pump. From there, I would recommend an encapsulation system to seal all the moisture from the ground and foundation from evaporating upward into the structure.

Leave a Reply

Barry Stone

Barry StoneKnown today as "America's House Detective," Barry advises readers from coast to coast about home inspection and real estate disclosure, providing honest clarity, fresh wit, consumer protection, and even-handed fairness in his responses to real estate questions. Read more.

  Ask The House Detective

  1.  *
  2.  *
  3.  *
  4.  *
  5. captcha

Order Barry's Book Now!

The Consumer Advocates Guide to Home Inspection

The Consumer
Advocates Guide to Home Inspection

$15.00includes shipping and handling

    Categories

    Agents Agents referring inspectors Aluminum wiring Asbestos ASHI As is Backdraft Banks Basement Bathroom Bedrooms Breaker panel Builder Liability Builders Building code Building contractors Buyer Beware Carbon Monoxide Central Heating System Certificate of occupancy Chimney Commercial real estate Complaints Concrete concrete pavement Contractor Copper piping Cottage cheese ceiling County Assessor Crawlspace CREIA Damage Deal Killers Demands Disclosure Double tapping Drainage Dryer exhaust ducts Dryrot Electrical Electric Radiant Heat Ethics FHA Appraisers Fireplace Fire wall Forced air French doors Furnace Gas Easement Gas piping Hard wood flooring Heat exchangers Heating System Hidden defects HOA Home inspection career Home Inspector Hot Water HUD Inspection advocacy Inspector Liability Inspector referral Inspector responsibility International Residential Code Investor Leaks Legal action Lot line Mold Municipal building inspectors NACHI NAHI National Electrical Code New Home New Realtor nternational Residential Code Permits Plumbers Plumbing Polybutlylene Pipe Radon Realtors Red Tagged Red tagged home Roof Safety San Luis Obispo Seller Seller Liability Septic System Setback Sewer line Shady inspection Shower Skylights Tenant Termites Tile roof Toilets Tree roots Uncategorized Unethical Home Inspector Uniform building code Unpermitted addition Unpermitted home Vapor barrier Ventilation Ventless gas fireplace Ventless Gas Fireplaces Ventless Gas Heater Very bad advice Wallpaper Water Heater Water stain Windows