Archive for the ‘Fire wall’ Category


Garage Firewall

Jun 20 2007

The House Detective by Barry Stone, Certified Home Inspector

Dear Barry: I have several questions involving garage firewalls. What materials should be used to finish a garage firewall? What type of entry door is required in a firewall between a garage and a house? Why are no penalties imposed on home inspectors who fail to report firewall violations? And finally, are sellers required to disclose firewall violations in a garage? Deb

Dear Deb: A garage firewall is commonly covered with 5/8-inch fire-rated drywall, with all seams taped. Wall penetrations such as ducts must be made of metal. A door through a firewall can be a solid core slab door with a minimum thickness of 1 3/8 inches, it can be a sheet metal door, or it can be a 20 minute fire-rated panel door. A fire door must also be self-closing, typically accomplished with a spring hinge.

Failure of a home inspector to disclose a substandard firewall or fire door is often a matter of professional negligence. A common exception would be a firewall that has 1/2-inch drywall only. Unless the edges of the drywall are exposed, it is not always possible to determine the thickness of the material.

Sellers are required to disclose defects of which they are aware. Most sellers, however, have no knowledge of firewall requirements and would be unaware of related violations.

The House Detective is distributed by 1000WattConsulting. Do not republish without written consent. To purchase reprint rights please contact marc@1000wattconsulting.com

Questions regarding home inspection please email Barry Stone at questions@housedetective.com

Barry Stone

Barry StoneKnown today as "America's House Detective," Barry advises readers from coast to coast about home inspection and real estate disclosure, providing honest clarity, fresh wit, consumer protection, and even-handed fairness in his responses to real estate questions. Read more.

  Ask The House Detective

  1.  *
  2.  *
  3.  *
  4.  *
  5. captcha

    Categories

    Agents Agents referring inspectors Aluminum wiring Asbestos ASHI As is Backdraft Banks Basement Bathroom Bedrooms Breaker panel Builder Liability Builders Building code Building contractors Buyer Beware Carbon Monoxide Central Heating System Certificate of occupancy Chimney Commercial real estate Complaints Concrete concrete pavement Contractor Copper piping Cottage cheese ceiling County Assessor Crawlspace CREIA Damage Deal Killers Demands Disclosure Double tapping Drainage Dryer exhaust ducts Dryrot Electrical Electric Radiant Heat Ethics FHA Appraisers Fire Damage Fireplace Fire wall Forced air French doors Furnace Gas Easement Gas piping Hard wood flooring Heat exchangers Heating System Hidden defects HOA Home inspection career Home Inspector Hot Water HUD Inspection advocacy Inspector Liability Inspector referral Inspector responsibility Insurance International Residential Code Investor Leaks Legal action Liability Lot line Mold Municipal building inspectors NACHI NAHI National Electrical Code New Home New Realtor nternational Residential Code Permits Plumbers Plumbing Polybutlylene Pipe Radon Realtors Red Tagged Red tagged home Roof Safety San Luis Obispo Seller Seller Liability Septic System Setback Sewer line Shady inspection Shower Skylights Tenant Termites Tile roof Toilets Tree roots Uncategorized Unethical Home Inspector Uniform building code Unpermitted addition Unpermitted home Vapor barrier Ventilation Ventless gas fireplace Ventless Gas Fireplaces Ventless Gas Heater Very bad advice Wallpaper Water Heater Water stain Windows